Bridge Inspector Technical Specifications

Main Display Unit TFT Touch Screen Type
Alternative 1 : Amber Monochrome
Alternative 2 : Colour (65,536 colors)
Main Processor Unit PLC (Programmable Logic Controller)
PLC Digital I/O Standard 36 (max 256)
Operation Modes (Protected) Automatic / Manual On / Manual Off
Auto Mode NMEA Speed 4,800 – 38,400 bps
NMEA 0183 Inputs 1 – 4 Serial Ports IEC 61162
Auto Mode Activation GPS/Heading Track Control IEC 61162
Speed Log Pulse Input (200 – 400 pulses)
Digital Free Contact NC / NO
Modbus PLC Ports 2
Ethernet PLC Port 1 (Optional)
Motion Sensors Ports Standard 2 (Expandable to 12)
Main Power Supply 110 – 230V AC 50 / 60Hz
Emergency Power Supply 24V DC
SELMA UPS 6 Hours independent Emergency Operation
System Configuration Security Removable Key / Password Protected (Master)
Dormant Period (Td) 3 -12 min
First Stage Warning Indication Active after Td
First Stage Alarm Td +15 sec
Second Stage Alarm Td +15 sec +15 sec
Third Stage Alarm Td +15 sec +15 sec +(90-180) sec * or omitted **
Bridge Remote Reset Stations Standard 6 (Expandable)
Watch Alarm, Emergency Call, Reset , Buzzer
Officers Cabin Station Standard 5 (Expandable)
Duty Call Lamp, Test Buzzer, Buzzer Activation
Public Spaces Sounders Standard 2 (Expandable)
Tamper Protection Separate Tamper Alarms Activation Protected
Supplementary PLC Outputs VDR, Ship General Alarm System
Optional NMEA Output $ALR, $AKN for VDR
Type Approved IMO MSC.128(75)
IEC60945 / IEC61162 / IEC62616:2010

* In larger vessels, the delay between the second and third stage alarms may be set to a longer value on installation, up to a maximum of 3 min, to allow sufficient time for the back-up officer and/or Master to reach the bridge.

** In vessels other than passenger vessels, the second or third stage remote audible alarms may sound in all the above locations at the same time. If the second stage audible alarm is sounded in this way, the third stage alarm may be omitted.

The following Installation Manuals (Vessel, Office and Class copies) are included with every Bridge Inspector – Bridge Navigational Watch Alarm System, at no extra charge.
  • Operation Manual
  • General Arrangement Cables Installation Plans
  • Electrical Connection Schematics
  • Bridge Interfaces Interconnection Plans (If Required)
  • Equipment Mounting Schematics
  • Material List
  • Technical Specification
  • Marine Certificates
Detailed technical specifications by module:
Main System:
Optional: